Gel electrophoresis, SDS-PAGE and Western blot
The essentials
- SDS denatures proteins and coats them with negative charge roughly in proportion to their length.
- In SDS-PAGE separation is by size: migration distance is roughly linear in log(molecular mass).
- Smaller proteins migrate farther; a ladder of known masses gives the apparent mass of a band.
- A reducing agent (DTT or β-mercaptoethanol) breaks disulfide bonds; Coomassie stains all proteins.
- A Western blot detects one protein with an antibody: it shows immunoreactivity at an apparent mass, not purity or activity.
In electrophoresis charged molecules move through a gel in an electric field. The gel, usually polyacrylamide for proteins or agarose for DNA, acts as a sieve that slows large molecules more than small ones.
Native proteins differ in charge and shape, so in SDS-PAGE they are first boiled with SDS (sodium dodecyl sulfate). SDS unfolds the chain and binds along it (about 1.4 g SDS per g protein), giving every protein a similar negative charge per unit length. A reducing agent breaks disulfide bonds, so subunits run separately. All proteins then move towards the positive electrode, and the only thing that matters is size: smaller proteins migrate farther. Over the useful range, migration distance falls linearly with log(molecular mass).
A ladder of proteins of known mass runs in a neighbouring lane. You estimate the apparent mass of a sample band by comparing its position with the ladder. A higher acrylamide percentage resolves small proteins better; a lower one suits large proteins.
Coomassie stain shows all proteins. In a Western blot the proteins are transferred to a membrane and probed with a specific antibody, so only the target appears. A band supports an immunoreactive species of that apparent mass; it does not prove the sample is pure or the protein is active.
In the 3D lab one slider sets the target mass (15-140 kDa) and moves its band; the other switches the detection between total-protein stain (three sample bands) and antibody (target only). Move the target from 15 to 140 kDa and watch the band climb towards the wells.
Interactive 3D model: move the sliders and watch what changes.
Chromatography and protein purification
The essentials
- Chromatography separates molecules by how they partition between a mobile and a stationary phase.
- Size exclusion (gel filtration): large molecules skip the pores and elute first; small ones elute later.
- Ion exchange separates by charge, affinity by specific binding (e.g. His-tag on Ni-NTA).
- Resolution for equal peaks: Rs = Δ(elution volume) / (4σ); Rs ≥ 1.5 means baseline separation.
- Yield = recovered target / starting target × 100%; purification fold = specific activity after / before.
In chromatography a sample is carried by a mobile phase (buffer) through a column packed with a stationary phase. Molecules that interact more with the stationary phase are delayed, so they leave the column (elute) later.
Size exclusion
Porous beads. Large proteins cannot enter the pores, travel the shortest path and elute first. Small molecules explore the pores and elute last.
Ion exchange
Charged beads bind proteins of opposite charge; a rising salt gradient elutes them in order of binding strength.
Affinity
A ligand on the beads binds the target specifically, e.g. a His-tag on Ni-NTA, eluted with imidazole.
Reversed phase
A hydrophobic surface retains hydrophobic molecules; used mostly for peptides.
Two peaks are useful only if they are separated. Resolution compares the distance between peak centres with their width. For two Gaussian peaks of equal width σ, the baseline width is about 4σ, and Rs = Δ/(4σ). Rs of about 1.5 or more means baseline separation; below 1 the peaks overlap strongly.
Purification is a balance: each step should raise purity (specific activity) while losing as little yield as possible.
In the 3D lab the sliders set the peak separation, the peak width σ and the recovered mass. More separation or narrower peaks move the bands apart and raise resolution; the recovery slider fills the collected fraction and changes the yield. Resolution and yield are different questions.
Interactive 3D model: move the sliders and watch what changes.
ELISA and immunoassay standard curves
The essentials
- Sandwich ELISA: capture antibody → antigen → detection antibody linked to an enzyme (e.g. HRP) → coloured product.
- Washing between steps removes unbound material; blocking prevents non-specific binding.
- Subtract the blank (background) before reading the standard curve.
- The standard curve saturates: near the plateau a small error in signal gives a large error in concentration.
- Dilute samples that fall near the plateau and multiply back by the dilution factor.
An ELISA (enzyme-linked immunosorbent assay) measures a specific molecule using antibodies in a plastic multiwell plate. In the common sandwich format a capture antibody is fixed to the well, the sample is added and the antigen binds, then a second detection antibody binds another part of the antigen. The detection antibody carries an enzyme such as horseradish peroxidase (HRP), which turns a colourless substrate (e.g. TMB) into a coloured product read as absorbance. Blocking with an inert protein and thorough washing reduce non-specific signal.
The signal is converted to concentration with a standard curve made from known amounts of antigen. First subtract the blank, the signal of a well without antigen. The curve is not a straight line: at high concentration the capture sites saturate and the signal reaches a plateau. In the flat region the slope is small, so a small error in absorbance becomes a large error in concentration. Samples are therefore diluted to fall in the steep, central part of the curve. Standard curves are usually fitted with a four-parameter logistic model.
In the 3D lab one slider sets the unknown concentration (1-100 ng/mL) and moves the well along the calibration curve; the other sets the background, which shifts every signal up by the same amount. Compare the observed and blank-corrected readouts, and notice how little the signal changes between 60 and 100 ng/mL.
Interactive 3D model: move the sliders and watch what changes.
Mass spectrometry and m/z
The essentials
- A mass spectrometer measures mass-to-charge ratio (m/z), not mass directly.
- For a protonated ion [M + zH]ᶻ⁺: m/z = (M + z × 1.0073) / z = M/z + 1.0073.
- Isotope peaks are 1.00335 Da apart in mass, so 1.00335/z apart in m/z: spacing reveals the charge.
- ESI gives multiply charged ions (good for proteins); MALDI mostly gives singly charged ions.
- Tandem MS (MS/MS) fragments peptides to read their sequence; peptide masses identify proteins against a database.
A mass spectrometer turns molecules into gas-phase ions, separates them by their mass-to-charge ratio (m/z) and counts them at a detector. The spectrum shows intensity against m/z.
Biomolecules are usually ionised gently. Electrospray ionisation (ESI) sprays a solution into fine droplets and often adds several protons, so a large protein appears at low m/z values with several charge states. MALDI uses a laser and a matrix and gives mostly singly charged ions. In positive mode each proton adds 1.0073 Da and one positive charge.
For an ion carrying z protons the formula is m/z = (M + z × 1.0073)/z = M/z + 1.0073, where M is the neutral mass. Doubling the charge roughly halves m/z.
Natural isotopes, mostly 13C, add peaks at +1, +2 Da above the monoisotopic peak. In m/z these peaks are 1.00335/z apart, so the spacing tells you the charge: 1 for z = 1, 0.5 for z = 2, 0.33 for z = 3. In proteomics, proteins are digested with trypsin; the peptide masses and their MS/MS fragment patterns are matched against a sequence database.
In the 3D lab one slider sets the neutral mass (200-2000 Da) and the other the charge (+1 to +5). Raising the mass moves all peaks to higher m/z; raising the charge moves them to lower m/z and squeezes the isotope peaks closer together. Peak heights are illustrative.
Interactive 3D model: move the sliders and watch what changes.
Quiz
30 questions in random order. The explanation appears after each answer.
Glossary cards
Read the word, try to say what it means, then tap the card to flip it.